Skip to main content

Reduced Ca2+ transport across sarcolemma but enhanced spontaneous activity in cardiomyocytes isolated from left atrium-pulmonary veins tissue of myopathic hamster

Abstract

Background

Several lines of evidence point to a particularly important role of the left atrium (LA) in initiating and maintaining atrial fibrillation (AF). This role may be related to the location of pulmonary veins (PVs) in the LA. The aim of the present study was to investigate the action potential (AP) and ionic currents in LA-PV cardiomyocytes isolated from Bio14.6 myopathic Syrian hamsters (36-57 week-old) versus age-matched F1B healthy control hamsters.

Methods and Results

Whole-cell patch-clamp techniques were used to record AP in current-clamp mode and ionic currents in voltage-clamp mode. The results obtained show that in both healthy and myopathic LA-PV tissue spontaneously discharging cardiomyocytes can be found, but they are more numerous in myopathic (9/29) than in healthy hamsters (4/42, p < 0.05 by χ2 analysis). Myopathic myocytes have shorter AP duration (APD) with smaller ICa,L and INCX than the healthy control. The currents ITO, IK, IK1 and ICa,T are not significantly different in myopathic versus healthy cells.

Conclusions

Our results indicate that in myopathic Syrian hamsters LA-PV cardiomyocytes are more prone to automatic rhythms. Also, they show altered electrophysiologic properties, which may be due to abnormal Ca2+ channels and may account for contractile dysfunction.

Introduction

The Biobreeders strain 14.6 myopathic Syrian hamster had been frequently used as an experimental model for the study of congestive heart failure (CHF) [13]. It has been proposed that, because of inherited defects in cytosolic calcium (Ca2+i) reuptake in the sarcoplasmic reticulum (SR) [4, 5], myopathic myocytes would be more prone to develop Ca2+i overload and related triggered arrhythmia [6]. In this animal, the evolution of the disease is characterized by (a) an early stage of cellular necrosis (40 to 60 days), (b) a mid-stage of cardiac hypertrophy and ventricular dilation (100 to 300 days), and (c) an end stage of de-compensated heart failure (>360 days).

Recently, an increased incidence of atrial fibrillation (AF) has been shown in patients with more advanced CHF [7]. In the left atrium (LA), the pulmonary veins (PVs) are an important source of ectopic beats, which frequently initiate paroxysms of AF. These foci respond to treatment with radio-frequency ablation [8, 9]. Previous studies in multiple or single cells from dogs [10, 11] and rabbits [12, 13] have shown that PVs contain cardiomyocytes, which may be either quiescent or show spontaneous activity. However, it is not clear whether CHF enhances the arrhythmogenic activity of PVs.

The aim of the present experiments was to study whether there are alterations in action potential and ionic currents in LA-PV myocytes of Biobreeders Syrian hamsters at mid- and late-stages of cardiac failure (36-57 week-old) compared to healthy hamsters of the similar age. A preliminary report has appeared in abstract form [14].

Materials and methods

Isolation of single PV cardiomyocytes

All experiments were performed according to institutional guidelines. Male cardiomyopathic hamsters (Bio14.6) and normal F1B hamsters purchased from Bio Breeders Inc. (Fitchburg, MA, USA) and aged 36 to 57 weeks, were used for the experiments. Hamsters were anesthetized with intraperitoneal injection of sodium pentobarbital (50 mg/kg). A mid-line thoracotomy was quickly performed along with removal of heart and lungs. The PVs were perfused in a retrograde manner via polyethylene tube passed through the aorta and left ventricle into the left atrium. The proximal end of the polyethylene tubing was connected to a Langendorff apparatus for perfusion with oxygenated Tyrode's solution at 37°C. The Tyrode's solution contained (in mmol/L) NaCl 137, KCl 5.4, CaCl2 1.8, MgCl2 0.5, HEPES 10 and glucose 11 (pH was adjusted to 7.4 with NaOH) for about 15 minutes until efferent fluid was without blood.

The perfusate was then replaced with oxygenated Ca2+-free Tyrode's solution containing 1 mg/ml collagenase (Sigma, Type I) and 0.01 mg/ml protease (Sigma, Type XIV) for 30-40 minutes. Afterwards, the heart was washed with oxygenated Ca2+-free Tyrode's solution for 10 minutes. After that, the LA-PV area was removed from the heart, cut into fine pieces and gently shaken in 5-10 ml high-K+ storage solution until single cardiomyocytes were obtained.

Cellular electrophysiology

Only LA-PV cardiomyocytes with clear cross striations obtained from 19 myopathic hamsters and 22 healthy hamsters were used for electrophysiological studies. Action potentials and ionic currents were recorded by means of whole-cell patch-clamp techniques with an Axopatch 1D amplifier (Axon Instruments, CA, U.S.A) as described in detail recently [11, 13, 15]. The standard pipette solution contained (in mmol/L) KCl 20, K aspartate 110, MgCl2 1, EGTA 0.5, Mg2ATP 5, Na2phosphocreatine 5, LiGTP 0.1, and HEPES 10, adjusted to pH 7.2 with KOH. The standard extracellular solution was the normal Tyrode's solution also used in cell isolation. Ionic currents were recorded in voltage-clamp mode. For the recording of the calcium currents ICa,L and ICa,T, tetraethylammonium (TEA) chloride and CsCl replaced NaCl and KCl, respectively. For ICa,T recording, tetrodotoxin (5 μmol/L) was added to block the fast Na+ current (INa). For K+ current measurement, CdCl2 (200 μmol/L) was added to block ICa,L. A 30-ms prepulse from -80 to -40 mV was used to inactivate the sodium channel, followed by a 300-ms test pulses in 10-mV increments to +60 mV. IK1 was quantified as 1 mmol/L Ba2+-sensitive current.

Action potentials (APs) were recorded in current-clamp mode. The tip potentials were zeroed before formation of the membrane-pipette seal in Tyrode's solution. After rupture, junction potential (8 mV) was corrected for AP recording. A small hyperpolarizing step from a holding potential of -50 mV to a testing potential of -55 mV was used to obtaining the total cell capacitance at the beginning of each experiment. The area under the capacitative current was divided by the applied voltage step to obtain the total cell capacitance. Normally 60-80% of series resistance (RS) was electronically compensated. After compensation, the average time constant was 71 ± 6 μs, (cell capacitance 33 ± 2 pF, for 83 cells in healthy group; and 47 ± 3 pF for 67 cells in myopathic group). The average RS was 1.8 ± 0.1 MΩ for all cells examined. Currents rarely exceeded 1.2 nA, and the maximal voltage error did not exceed 3 mV.

Voltage command pulses were generated by a 12-bit digital-to-analog converter controlled by pCLAMP software (Axon Instruments). APs were elicited by pulses of 2 ms and 90 mV at a rate of 1 Hz. AP measurements were begun 3 minutes after cell membrane rupture, and the steady-state AP duration was measured at 20% (APD20), 50% (APD50) and 90% (APD90) of full repolarization. Depolarization-induced currents included the transient outward K+ current (ITO) and the delayed rectifier outward K+ current (IK), and were elicited by applying steps from a holding potential (Vh) of -40 mV in 10 mV increment up to +60 mV at a frequency of 0.1 Hz.

In recording calcium currents, to minimize the effect of "rundown" [13], the depolarizing steps were applied from a holding potential which was alternated between -90 mV and -50 mV. Also the steps were applied between 5 and 15 minutes after rupturing the membrane patch. ICa,L was measured as inward current during depolarizing 300 ms steps applied from the holding potential of -50 mV in 10 mV increments up to +60 mV. ICa,T was separated from ICa,L by subtraction of currents elicited by 300 ms depolarizing steps from holding potentials of -50 and of -90 mV in increments of 10-mV up to +60 mV. The calcium currents were measured as the difference between the inward peak and the current remaining at the end of the voltage step.

The background current IK1 was measured during steps from holding potential of -40 mV in 10 mV increments to test potentials ranging from -20 to -120 mV at a frequency of 0.1 Hz. The holding potential of -40 mV was used to inactivate the sodium channel. For measurement of Na+-Ca2+ exchange current (NCX), the external solution (in mM) consisted of NaCl 140, CaCl2 2, MgCl2 1, HEPES 5, and glucose 10 with a pH of 7.4, and contained strophanthidin (4 μM) nitredipine (10 μM) and niflumic acid (15μM). Test steps were applied from a holding potential of -40 mV to test potentials of -100, -80, -60, -40, -20, 0, +20, +40, +60, +80 and +100 mV.

Statistics

All quantitative data are expressed as mean ± S.E.M. The differences between healthy and myopathic cardiomyocytes were analyzed by one-way ANOVA. The χ2 test with Yates' correction of Fisher's exact test was used for the categorical data. A value of p < 0.05 was considered to be statistically significant.

Results

Action potential characteristics

In driven cardiomyocytes, APD50 and APD90 were shorter in myopathic (n = 29) than in healthy hamsters (n = 42). Figure 1A and 1B show typical examples. The difference in APD between the two types of cells was statistically significant (Table 1). Myopathic myocytes had a larger capacitance (Table 1) and thus a larger cell size. Other AP parameters (APA and MDP) were not significantly different between the two groups.

Figure 1
figure 1

Different configuration and duration of driven action potentials in LA-PV cardiomyocytes obtained from healthy (panel A) and myopathic (panel B) hamsters.

Table 1 Electrophysiological properties of healthy and myopathic LA-PV cardiomyocytes isolated from 18 healthy and 17 myopathic Syrian hamsters

In the absence of electric stimulation, the LA-PV cardiomyocytes could be spontaneously active. As illustrated in Figure 2, spontaneous APs had a slow rate of rise of the upstroke and a conspicuous diastolic depolarization, similar to those of pacemaker cells in the sinoatrial node (SA node). Spontaneously active cardiomyocytes were present in both myopathic and healthy LA-PV areas, but they were more numerous in myopathic hamsters (9/29) than in healthy hamsters (4/42) (χ2 = 3.966, p < 0.05).

Figure 2
figure 2

Spontaneously discharging action potentials in the absence of electrical stimulation recorded in a LA-PV cardiomyocyte.

Early (EAD) and late (DAD) afterdepolarizations

Triggered rhythms (EAD and DAD) in myopathic LA-PV cardiomyocytes driven at 1 Hz are shown in Figure 3. EAD were present in 5 out of 29 (17%) myopathic and in 4 out of 42 (10%) healthy LA-PV cardiomyocytes. The incidence of DAD was 2/29 (7%) and 8/42 (19%) in myopathic and healthy myocytes, respectively. There were no significant differences in the incidence of EAD and DAD between the two groups. However, it is not readily apparent why EADs and DADs should be present in both normal and myopathic cells.

Figure 3
figure 3

Triggered rhythms in hamster LA-PV cardiomyocyte. Panel A and B show typical examples of early and delayed afterdepolarization (EAD and DAD, respectively) recorded in a myopathic myocyte stimulated at a rate of 1 Hz in normal Tyrode's solution.

L- and T-type Ca current (ICa,L, ICa,T)

Selected membrane current traces elicited by depolarizing steps from Vh -90 mV (I) and -50 mV (II, ICa,L) in healthy (panel A) and myopathic (panel B) LA-PV myocytes are illustrated in Figure 4. The difference current (I-II, ICa,T) arise from the subtraction of current elicited from Vh -90 mV and -50 mV, respectively.

Figure 4
figure 4

Differences in two types of calcium currents recorded from healthy and myopathic LA-PV cardiomyocytes. A and B: selected membrane currents elicited by depolarizing clamps to various voltages from the holding potentials (Vh) of -90 mV (I) and -50 mV (II, ICa,L). Horizontal arrows near left margin indicate zero current. The difference current (I-II, ICa,T) was obtained from the subtraction of current elicited from -90 mV and -50 mV, respectively. C: Mean current densities of peak ICa,L and ICa,T from 10 myopathic and 12 healthy LA-PV myocytes. *P < 0.05 by group comparisons.

The voltage-dependence of peak ICa,L and ICa,T density from 12 healthy and 10 myopathic LA-PV myocytes is shown in panel C. The current-voltage relationship of ICa,T had a threshold voltage of about -40 mV and a peak at -20 mV. The current-voltage relationship of ICa,L had a threshold voltage about -20 mV and a peak at +20 mV. ICa,T was activated at more negative voltage than ICa,L and its density was three-fold smaller than that of ICa,L. The result shows that myopathic myocytes had smaller ICa,L than healthy myocytes (-4.6 ± 0.98 versus -7.8 ± 0.75 pA/pF, p < 0.05). The ICaT was also appeared smaller in myopathic myocytes but the difference between myopathic vs. healthy was not statistically significant.

Transient outward K current (ITO)

ITO was studied with a double-pulse protocol (Figure 5). A 30-ms prepulse from -80 to -40 mV was used to inactivate the sodium channel, followed by a 300-ms test pulse to +60 mV in 10-mV increments. Selected membrane currents in healthy (panel A) and myopathic (panel B) LA-PV myocytes are illustrated in Figure 5. There were no statistically significant differences in voltage-dependent properties of ITO in myopathic versus healthy hamsters.

Figure 5
figure 5

Transient outward K+ current (I TO ) activated on depolarization in healthy (panel A) and myopathic LA-PV myocytes (panel B). Clamp protocol is shown on top of panel B. The mean current-voltage relations of ITO in 23 healthy (closed circles) and 17 myopathic myocytes (open circles) are shown in panel C.

Delayed rectifier K current (IK)

Long (1 s) depolarizing steps from Vh -40 to +60 mV in 10 mV increments (see protocol on Figure 6) induced a slowly activating and non-inactivating outward current, consistent with the behavior of delayed rectified K+ current in hamster LA-PV myocytes. In addition, there was ITO with rapid activation kinetics. The voltage-dependence of IK was comparable in myopathic and healthy hamsters (Figure 6C).

Figure 6
figure 6

Delayed outward K+ current (I K ) activated on depolarization in LA-PV healthy (panel A) and myopathic myocytes (panel B). Clamp protocol is shown at the top of panel B. IK was measured near the end of the 1 s depolarizing pulses. Downward solid triangle indicated IK recorded at test potential of +60 mV. In contrast, open triangle indicated ITO in the same myocytes. Panel C shows the mean current-voltage relations of IK in 45 healthy (closed circles) and 34 myopathic myocytes (open circles).

Inward rectifier K current (IK1)

IK1 was measured in the absence and presence of 1 mmol/L Ba2+ as illustrated in Figure 7. The Vh was -40 mV and then IK1 was measured at test potentials over the range from -20 down to -120 mV (see clamp protocol on top of Figure 7). The difference in the magnitude of IK1 in control solution and solution containing Ba2+ gave the Ba2+-sensitive inward rectifier K currents. As shown in Figure 7 panel C, the mean Ba2+-sensitive IK1 was not significantly different between the two groups.

Figure 7
figure 7

Ba2+-sensitive inward rectifier K+ current, I K1 . Panel A illustrates a series of IK1 elicited on hyperpolarization before (control) and after 1 mM Ba2+ superfusion in a healthy myocyte. Similar traces obtained from a myopathic myocyte are shown in panel B. Horizontal arrows near left margin indicate zero current. The difference current densities (Ba2+-sensitive K+ current, IK1) (mean ± S.E.M.) in 14 healthy myocytes and 12 myopathic myocytes are summarized in the current-voltage relations shown in panel C.

Na+-Ca2+ exchange current (INCX)

The protocol tested is shown in Figure 8 (top). In Figure 8 Vh was -40 mV to inactivate fast Na channel. For inward NCX currents the cardiomyocytes were hyperpolarized to -100~ -60 mV in 20 mV steps from a Vh of -40 mV. For outward NCX currents, the myocytes were depolarized from Vh -40 to +100 mV in 20 mV increments. Both the inward and outward INCX were smaller in the myopathic (panel B) than in the healthy cells (panel A). As shown in the current-voltage relationship of INCX (Figure 8, panel C), the difference between the mean outward and inward NCX currents in myopathic cells (n = 5) was significantly smaller than in healthy myocytes (n = 6)

Figure 8
figure 8

Na+-Ca2+ exchange current (NCX) in healthy (panel A) and myopathic LA-PV myocytes (panel B). The clamp protocol is shown between panels A and B. The holding potential was -40 mV. Horizontal arrow at left margin indicates zero current. For inward NCX currents the myocyte was hyperpolarized Vh -40 to -100 mV in 20 mV increments. For outward NCX currents, the myocyte was depolarized from -40 to +100 mV in 20 mV increments. Mean current-voltage relationships of NCX in 6 healthy and 5 myopathic myocytes (from 3 hamsters in each group) are summarized in panel C.

Discussion

The present results show that the LA-PV cardiomyocytes obtained from the myopathic hamsters at mid- and late-stage of cardiac hypertrophy and dilatation (36-57 week-old) have higher percentage of spontaneously active cardiomyocytes than control myocytes from healthy hamsters. When driven at constant rate, the myopathic myocytes have shorter APD. Also, ICa,L and INCX are smaller in myopathic than in healthy control and this might account for the shorter APD. The currents ITO, IK, IK1 and ICa,T were not significantly different in the two groups. Our results suggest that LA-PV cardiomyocytes of myopathic hamsters have more frequently automatic discharge, but smaller ICa,L and INCX with a shorter APD. The altered electrophysiological properties might favor the occurrence of reentrant rhythms [6, 16].

Automatic rhythms

It has been demonstrated in human myocardium that there are myocardial cells in the junction between atrium and PV [17, 18]. In isolated guinea-pig PV tissues, infusion of noradrenaline (10-7 g/ml) can induce spontaneous tachyarrhythmias [19]. Our recent study on PV tissues of dog [1, 11] and rabbit [12, 13] also demonstrated that PV myocardial sleeves have some cells that can be spontaneously active. In the present experiments, myocytes of myopathic hamsters had automatic activity that was significantly more frequent (31%) than those from healthy hamster (10%,). Thus, the myopathic PVs are more prone to develop automatic arrhythmias.

The increase in automaticity of the myopathic PV cardiomyocytes could be related to one or more of the following ionic mechanisms: an increased ICa,T[20], an enhanced decay in IK during diastole, a positive shift of the diastolic potential or a negative shift of the threshold potential or a shorter APD [6, 16]. The present electrophysiological results suggest that the significant shorter APD (and presumably a shorter refractory period) with an increased slope of diastolic depolarization may be the most likely factors in the abnormal rhythms.

Triggered rhythms

Myopathic PV cardiomyocytes tend to develop EAD and DAD which could initiate repetitive discharge. Yet, the incidences of triggered activities in myopathic myocytes were not significantly higher than those of healthy PV cardiomyocytes. Arrhythmias in myopathic myocytes could also be related to the significant shorter APD50 and APD90 (Table 1), which could facilitate re-entry rhythms through a shorter refractory period. The shorter APs could be related to the smaller calcium currents.

The significantly smaller ICa,L could result in a smaller intracellular Ca2+ concentration ([Ca2+]i) in myopathic myocytes and therefore be less likely to generate [Ca2+]i overload and transient inward curren ITI on repolarization from depolarizing steps [6, 21]. On the other hand, release of Ca2+ from the SR could inactivate the L-type Ca2+ channels [22] thus resulting in a smaller ICa,L. Further experiments using fluorescent method to measure [Ca2+]i and using whole-cell patch-clamp technique to determine ITI in myopathic vs. healthy cardiomyoyctes need be carried out to clarify this point.

Reentrant rhythms

Hano et al. [23] reported that spontaneous and sporadic ventricular premature contractions (VPC) occurred in 8.3% of Bio14.6 strain cardiomyopathic hamsters, whereas no ventricular arrhythmia was recorded in normal hamsters. Either non-sustained ventricular tachycardia (NSVT) or ventricular fibrillation could be induced in all cardiomyopathic hamsters. In contrast, neither NSVT nor ventricular fibrillation was induced in normal hamsters [23].

Cold-immobilization of Bio14.6 myopathic hamsters for 2 hr had a lethal effect [24]. There was an obvious heart rate slowing and occasional AF or atrio-ventricular block. In contrast, no ill effects were observed in healthy hamsters subjected to similar stress. Propranolol (but not phentolamine or atropine) prevented the lethal effects of the stress. Higher incidence of automatic activity in the presence of shorter APD and/or refractory period could lead to generation of ventricular arrhythmias [23] but could not explain the atrial arrhythmias [24]. Sakamoto [25] summarized the electrical and ionic abnormalities in the heart of cardiomyopathic hamsters and noted the contradictory results from different or even from the same laboratory. Species difference and ages of animals should be considered in the interpretation of the experimental results. Also, reduced coupling of the myocytes in the PV due to histological changes in extracellular collagen matrix in chronic atrial pacing- induced AF may provide an additional mechanism facilitating repetitive rapid activities [26].

Similarity and difference in arrhythmogenic mechanisms in myopathic hamster versus Xinα-deficient mouse model

We have recently reported a study on the mechanisms of arrhythmias in the LA-PV myocardium of mXin-deficient mice induced by brief high frequency electrical drive (30 Hz for 3 sec) [27] in the absence and presence of isoproterenol, strophanthidin and atropine. It was found that automatic rhythms, triggered rhythms and induction of reentrant AF were affected differently by mXinα gene deletion as detected by a MED64 multi-electrode array system [27]. The induction of AF was consistently hindered in mXinα-deficient LA-PV preparations even under conditions that enhance its induction in mXinα+/+ preparations. The mechanisms that prevent the induction of AF in the mXinα-/- preparation appear to involve a decrease in conduction velocity and longer APs: these changes apparently prevent the establishment of reentry paths [27]. However, automatic and triggered rhythms were not suppressed in mXinα-/- preparations.

In contrast to murine cardiomyocytes, the APD of LA-PV cardiomyocytes of myopathic hamster was significantly shorter than that of healthy control (see Figure 2 and Table 1). A shorter AP may favor the generation of reentrant rhythms. Since the incidence of triggered activities in myopathic myocytes was not significantly higher than that in healthy control, other factors such as age-related changes in Na+-Ca2+ exchanger have been considered [28, 29]. However, the present results show that both inward and outward Na+-Ca2+ exchange current was reduced in the LA-PV cardiomyocytes of myopathic hamsters (Figure 8). Therefore, INCX is unlikely to contribute to enhanced automatic rhythms in Bio14.6 hamsters. Further experiments are required to clarify the underlying mechanisms responsible for the arrhythogenesis in myopathic Bio14.6 hamsters.

Abbreviations

APD:

action potential duration

Bio14.6 and F1B:

Syrian hamsters strains Bio14.6 and F1B

LA:

left atrium

PVs:

pulmonary veins

AF:

atrial fibrillation

References

  1. Gertz EW: Cardiomyopathic Syrian hamster: a possible model of human disease. Prog Exp Tumor Res. 1972, 16: 242-247.

    Article  CAS  PubMed  Google Scholar 

  2. Homburger F: Myopathy of hamster dystrophy: history and morphologic aspects. Ann NY Acad Sci. 1979, 317: 1-7.

    Article  CAS  PubMed  Google Scholar 

  3. Thuringer D, Deroubaix E, Coulombe A, Coraboeuf E, Mercadier JJ: Ionic basis of the action potential prolongation in ventricular myocytes from Syrian hamsters with dilated cardiomyopathy. Cardiovasc Res. 1996, 31: 747-757.

    Article  CAS  PubMed  Google Scholar 

  4. Kuo TH: Defective Ca2+-pumping ATPase of heart sarcolemma from cardiomyopathic hamster. Biochim Biophys Acta. 1987, 900: 10-16. 10.1016/0005-2736(87)90272-0.

    Article  CAS  PubMed  Google Scholar 

  5. Chiesi M, Wrzosek A, Gryueninger S: The role of the sarcoplasmic reticulum in various types of cardiomyocytes. Mol Cell Biochem. 1994, 130: 159-171. 10.1007/BF01457397.

    Article  CAS  PubMed  Google Scholar 

  6. Waldo AL, Wit AL: Mechanisms of cardiac arrhythmias. Lancet. 1993, 341: 1189-1193. 10.1016/0140-6736(93)91012-B.

    Article  CAS  PubMed  Google Scholar 

  7. Ehrlich JR, Nattel S, Hohnloser SH: Atrial fibrillation and congestive heart failure: specific considerations at the intersection of two common and important cardiac disease sets. J Cardiovasc Electrohysiol. 2002, 13: 399-405. 10.1046/j.1540-8167.2002.00399.x.

    Article  Google Scholar 

  8. Haissaguerre M, Jais P, Shah DC, Takahashi A, Hocini M, Quiniou G, Garrigue S, Le Mouroux A, Le Metayer P, Clementy J: Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med. 1998, 339: 659-666. 10.1056/NEJM199809033391003.

    Article  CAS  PubMed  Google Scholar 

  9. Chen SA, Hsieh MH, Tai CT, Tsai CF, Prakash VS, Yu WC, Hsu TL, Ding YA, Chang MS: Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: electrophysiological characteristics, pharmacologic responses, and effects of radiofrequency ablation. Circulation. 1999, 100: 1879-1886.

    Article  CAS  PubMed  Google Scholar 

  10. Chen YJ, Chen SA, Chang MS, Lin CI: Arrhythmogenic activity of cardiac muscle in pulmonary veins of the dog: implication for the genesis of atrial fibrillation. Cardiovasc Res. 2000, 48: 265-273. 10.1016/S0008-6363(00)00179-6.

    Article  CAS  PubMed  Google Scholar 

  11. Chen YJ, Chen SA, Chen YC, Yeh HI, Chan P, Chang MS, Lin CI: Effects of rapid atrial pacing on the arrhythmogenic activity of single cardiomyocytes from pulmonary veins: implication in initiation of atrial fibrillation. Circulation. 2001, 104: 2849-2854. 10.1161/hc4801.099736.

    Article  CAS  PubMed  Google Scholar 

  12. Chen YJ, Chen SA, Chen YC, Yeh HI, Chang MS, Lin CI: Electrophysiology of single cardiomyocytes isolated from rabbit pulmonary veins: implication in initiation of focal atrial fibrillation. Basic Res Cardiol. 2002, 97: 26-34. 10.1007/s395-002-8384-6.

    Article  PubMed  Google Scholar 

  13. Chen YC, Chen SA, Chen YJ, Tai CT, Chan P, Lin CI: T-type calcium current in electrical activity of cardiomyocytes isolated from rabbit pulmonary vein. J Cardiovasc Electrophysiol. 2004, 15: 567-571.

    Article  PubMed  Google Scholar 

  14. Loh YX, Chen YC, Lin CI: Electrophysiology of single cardiomyocytes isolated from left atrium and pulmonary veins of myopathic versus healthy hamsters. (Abstract). The 31st International Congress on Electrocardiology, Kyoto, Japan, June 27-July 1. 2004, 145-

    Google Scholar 

  15. Wu SH, Chen YC, Higa S, Lin CI: Oscillatory transient inward currents in ventricular myocytes of healthy versus myopathic Syrian hamster. Clin Exp Pharmacol Physiol. 2004, 31: 668-676. 10.1111/j.1440-1681.2004.04082.x.

    Article  CAS  PubMed  Google Scholar 

  16. Vassalle M: The vicissitudes of the pacemaker current IKdd of cardiac Purkinje fibers. J Biomed Sci. 2007, 14: 699-716. 10.1007/s11373-007-9182-2.

    Article  CAS  PubMed  Google Scholar 

  17. Nathan H, Eliakim M: The junction between the left atrium and the pulmonary veins: An anatomic study of human hearts. Circulation. 1966, 34: 412-422.

    Article  CAS  PubMed  Google Scholar 

  18. Saito T, Waki K, Becker AE: Left atrial myocardial extension onto pulmonary veins in humans: Anatomic observations relevant for atrial arrhythmias. J Cardiovasc Electrophysiol. 2000, 11: 888-894. 10.1111/j.1540-8167.2000.tb00068.x.

    Article  CAS  PubMed  Google Scholar 

  19. Cheung DW: Electrical activity of the pulmonary vein and its interaction with the right atrium in the guinea-pig. J Physiol (Lond). 1981, 314: 445-456.

    Article  CAS  Google Scholar 

  20. Sen L, Smith TW: T-type Ca2+ channels are abnormal in genetically determined cardiomyopathic hamster hearts. Circ Res. 1994, 75: 149-155.

    Article  CAS  PubMed  Google Scholar 

  21. Vassalle M, Lin CI: Calcium overload and cardiac function. J Biomed Sci. 2004, 11: 542-565. 10.1007/BF02256119.

    Article  CAS  PubMed  Google Scholar 

  22. Morad M: Sigaling of calcium release in cardiac muscle. Molecular Physiology and Pharmacology of Cardiac Ion Channels and Transporters. Edited by: Morad M, Ebashi S, Trautwein W, Kurachi Y. 1996, Dordrecht, Kluwer Academic Publishers, 375-380.

    Chapter  Google Scholar 

  23. Hano O, Mitsuoka T, Matsumoto Y, Ahmed R, Hirata M, Hirata T, Mori M, Yano K, Hashiba K: Arrhythmogenic properties of the ventricular myocardium in cardiomyopathic Syrian hamster, Bio14.6 strain. Cardiovasc Res. 1991, 25: 49-57. 10.1093/cvr/25.1.49.

    Article  CAS  PubMed  Google Scholar 

  24. Matsuoka N, Arakawa H, Kodama H, Yamaguchi I: Characterization of stress-induced sudden death in cardiomyopathic hamsters. J Pharmacol Exp Ther. 1998, 284: 125-135.

    CAS  PubMed  Google Scholar 

  25. Sakamoto A: Electrical and ionic abnormalities in the heart of cardiomyopathic hamsters: In quest of a new paradigm for cardiac failure and lethal arrhythmia. Mol Cell Biochem. 2004, 259: 183-187. 10.1023/B:MCBI.0000021371.62090.f8.

    Article  CAS  PubMed  Google Scholar 

  26. Chiu YT, Wu TJ, Wei HJ, Cheng CC, Lin NN, Chen YT, Ting CT: Increased extracellular collagen matrix in myocardial sleeves of pulmonary veins: an additional mechanism facilitating repetitive rapid activities in chronic pacing-induced sustained atrial fibrillation. J Cardiovasc Electrophysiol. 2005, 16: 753-759. 10.1046/j.1540-8167.2005.40794.x.

    Article  PubMed  Google Scholar 

  27. Lai YJ, Huang EYK, Yeh HI, Chen YL, Lin JJC, Lin CI: On the mechanisms of arrhythmias in the myocardium of mXinα-deficient murine left atrial-pulmonary veins. Life Sci. 2008, 83: 272-283. 10.1016/j.lfs.2008.06.020.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  28. Wagner JA, Weisman HF, Snomann AM, Reynolds IJ, Weisfeldt ML, Snyder SH: Alterations in calcium antagonist receptors and sodium-calcium exchange in cardiomyopathic hamster tissues. Circ Res. 1989, 65: 105-214.

    Article  Google Scholar 

  29. Ju YK, Allen DG: Intracellular calcium and Na+-Ca2+ exchange current in isolated toad pacemaker cells. J Physiol (Lond). 1998, 508.1: 153-166.

    Article  Google Scholar 

Download references

Acknowledgements

The present works were supported by grants NSC 93-2320-B016-031, 94-2320-B016-035 and 98-2320-B016-010-MY3 (C.I.L.) from National Science Council, Chen-Han Foundation for Education (C.H.H.) and Cheng-Hsin General Hospital grant 94-02 (J.W.), Taipei, Taiwan, ROC.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Cheng-I Lin.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

YXL: performed most of the experimental works except study on NCX current and data analysis. KHW: performed the experimental works on NCX currents and data analysis. YCC: designed the experimental protocols for measurements of ionic currents and general instructions for patch-clamp study. CHH: discussion on experimental data (especially those for NCX currents), grant support for the experimental study. JW: general discussion on the experimental works and grant support for the study. CIL: principal investigator of the study, research grant applications to NSC, design of the electrophysiological study, data analysis and interpretation and writing up of the manuscript.

Authors’ original submitted files for images

Rights and permissions

Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://creativecommons.org/licenses/by/2.0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Loh, YX., Wu, KH., Chen, YC. et al. Reduced Ca2+ transport across sarcolemma but enhanced spontaneous activity in cardiomyocytes isolated from left atrium-pulmonary veins tissue of myopathic hamster. J Biomed Sci 16, 114 (2009). https://doi.org/10.1186/1423-0127-16-114

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1423-0127-16-114

Keywords